Load the software from the ATA card mounted in the PCMCIA slot #0. The office data is loaded from the ATA card mounted in the PCMCIA slot #1. After loading, the office data is saved to the ATA card mounted in the PCMCIA slot #0.
Figure 10-25: FLASH_UP_SAVE Mode
Procedure
1.Turn off the power of the ATM Switch.
2.Insert the new version ATA card in PCMCIA slot #0 and the ATA card containing the office data you wish to continue to use in PCMCIA slot #1.
3.Turn on the power of the ATM Switch and start the boot monitor.
4.Set the boot mode as follows:
BOOT# SET boot flash_up_save
5.End the boot monitor:
BOOT# QUIT