Installation

Setting System Configuration Data

 

 

 

 

Line Interface Test

Test the line interface of the line cards installed in the ATM Switch by entering a command from the MAT.

1.Enter the command for performing the line operation test. The command should be entered as follows:

DISPLAY line[RETURN]

2.After entering the command, response of the lines for which line cards are installed is displayed.

3.Make sure that “GOOD” is the response for all lines for which line cards are installed. No response is displayed for a line for which no line card is installed. This completes the operation test. The ATM Switch can now be used properly.

 

NOTE

 

 

Follow the instructions below when using the equipment in a country or region

 

 

 

 

 

where it must conform to EMI VCCI Type 1, FCC Class A, or EN55022 Class A.

 

 

 

 

 

 

 

 

 

 

 

Coaxial cable

 

 

 

 

As shown in the illustration below, install a ferrite core near the connector so

 

 

 

 

the cable makes a loop.

 

 

 

 

 

 

 

 

 

 

Figure 7-14: Ferrite Core Installation

RS-232C cable

Use a metal connector

Use a shielded cable

Securely fasten the metal connector to the main unit

Centillion 1200N ATM Switch User Manual

7-19

NTP 297-8103-903

 