Connection Management | Software Specifications |
|
|
|
|
The number of connections per system is as follows:
■ | 8,000 connections |
■
■ | 4,000 connections |
■
The ATM Switch also supports two connections, Soft PVC and tunneling, that take advantage of the characteristics of PVC and SVC mentioned above.
Soft PVC is a PVPC (Permanent Virtual Path Connection) or a PVCC (Permanent Virtual Circuit Connection) that is established by SVC procedure over several switches.
The ATM Switch allows the user to register up to 64 Soft PVCs. To use the Soft
PVC service, the remote side switch must be a NETNEX ATM Switch.
Tunneling is a connection that is established over a PVP (Permanent Virtual Path) network (e.g., existing public network that does not support SVC).
A VP (Virtual Path) is established in a physical link that connects the switches in a PVP network, and the VP is used as a tunneling path. The switch (edge switch) that is adjacent to the PVP network establishes PVCs in the tunneling path and sends SVC setup messages. The ATM Switch allows the user to register up to 64 tunneling paths. Figure
Figure 5-1: The ATM Switch Connections
Connections are established by inputting commands from a MAT connected to the ATM Switch. The information on the established connection can be read by a command from the MAT or sending a GET request from an NMS. (For details on the commands, refer to the ATM Command Manual.)
Centillion 1200N ATM Switch User Manual | |
| NTP |