Connection Management

Software Specifications

 

 

 

 

The number of connections per system is as follows:

Point-to-point (PVC):

8,000 connections

Point-to-multipoint (PVC): 1,000 connections

Point-to-point (SVC):

4,000 connections

Point-to-multipoint (SVC): 1,000 end points

The ATM Switch also supports two connections, Soft PVC and tunneling, that take advantage of the characteristics of PVC and SVC mentioned above.

Soft PVC is a PVPC (Permanent Virtual Path Connection) or a PVCC (Permanent Virtual Circuit Connection) that is established by SVC procedure over several switches.

The ATM Switch allows the user to register up to 64 Soft PVCs. To use the Soft

PVC service, the remote side switch must be a NETNEX ATM Switch.

Tunneling is a connection that is established over a PVP (Permanent Virtual Path) network (e.g., existing public network that does not support SVC).

A VP (Virtual Path) is established in a physical link that connects the switches in a PVP network, and the VP is used as a tunneling path. The switch (edge switch) that is adjacent to the PVP network establishes PVCs in the tunneling path and sends SVC setup messages. The ATM Switch allows the user to register up to 64 tunneling paths. Figure 5-1is a conceptual diagram of the connections supported by the ATM Switch.

Figure 5-1: The ATM Switch Connections

Connections are established by inputting commands from a MAT connected to the ATM Switch. The information on the established connection can be read by a command from the MAT or sending a GET request from an NMS. (For details on the commands, refer to the ATM Command Manual.)

5-2

Centillion 1200N ATM Switch User Manual

 

NTP 297-8103-903

Page 54
Image 54
Panasonic 1200N manual ATM Switch Connections