Basic Configuration and Setup

Setting up LAN Emulation

 

 

 

 

11.For the PNNI interface port 00, set a PNNI connection. Use values, VPI=0 and VCI=18.

SET pnni 00 0 18

12.Manually register an address of LECS to the switch. Upon an ILMI query of the LECS address from a prospective LE client, the switch will inform the LECS address registered with this command.

SET configserver 0 4700790000000000000000000077777777777700

LECS ATM address

LECS index (Up to 4 LECS can be registered.)

13.Save the configuration data you have just entered.

SAVE

14.Confirm that SVCLINE mode for connected line interface ports are enabled.

DISPLAY svcline [slot number][port number]

15.Confirm that dynamic SVC connections are established for connected line interface ports.

DISPLAY dynamicroute [slot number][port number]

16.Confirm that SVC connections for each connected line interface ports.

DISPLAY svc [slot number][port number]