Paradyne Hotwire M/SDSL and HDSL2 Termination Units, 8747 Table A-9. Cross-Connect Mode Options

Models: Hotwire M/SDSL and HDSL2 Termination Units 8777 8747 8779

1 167
Download 167 pages 40 Kb
Page 103
Image 103

Configuration Options

Table A-9. Cross-Connect Mode Options

(Cross-Connect Mode)

Possible Settings: DS1 Bypass, DS1 Cross-connect, DS0 Cross-connect,

Not Assigned, Disabled, Unframed Default Setting: DS1 Bypass

Determines the cross-connect mode for the port.

DS1 Bypass – The entire DSX-1 or G.703 interface is connected directly to the DSL interface.

DS1 Cross-connect– The entire DSX-1 or G.703 interface is connected through cross-connect circuitry to the DSL port.

DS0 Cross-connect– Individual time slots of the DSX-1 or G.703 interface may be connected to any time slot of any of the DSL interfaces.

Unassigned – None of the time slots associated with the port are assigned.

Unframed – (Model 8779 only.) Framing is disabled on the port. Since there are no time slots, the port is set to DS1 Bypass mode. This value is displayed but cannot be entered.

Disabled – The DSX-1 or G.703 port is disabled. No time slot assignments can be made to the port. To enable the port use the DSX-1 Interface or G.703 Interface screen. This value is displayed but cannot be entered.

8700-A2-GB20-00

April 2000

A-19

Page 103
Image 103
Paradyne Hotwire M/SDSL and HDSL2 Termination Units, 8747, 8777, 8779 manual Table A-9. Cross-Connect Mode Options