Monitoring and Troubleshooting

Self-Test Results Messages

The results of the last power-on or reset self-test appear in the middle column of the System and Test Status screen.

Table 7-2. Self-Test Results Messages (1 of 2)

Message

What Message Indicates

What To Do

 

 

 

CPU Fail

The Central Processing Unit failed

1. Reset the unit and try again.

 

internal testing.

2. Call your service

 

 

CPU CPLD

The Complex Programmable Logic

representative for assistance.

 

Fail

Device serving the Central

 

 

Processing Unit failed.

 

 

 

 

Data Path

The port shown failed to loop data on

 

Fail, Pt n

the full data path test.

 

 

 

 

DeviceFailed

One or more of the unit’s integrated

 

 

circuits has failed device-level

 

 

testing.

 

 

 

 

DSL

The DSL framer for Ports 1–4

 

Framer x Fail

(Framer A) or 5–8 (Framer B) failed.

 

 

 

 

DSL xcvr

The DSL transceiver failed on Port n.

 

Fail, Pt n

 

 

 

 

 

DSX-1

The unit failed to internally loop data

 

Failed, Pt n

on the DSX-1 Port n.

 

 

 

 

DTE

The DTE framer for Ports 1–4

 

Framer x Fail

(Framer A) or 5–8 (Framer B) failed.

 

 

 

 

DTE LIU x

The DTE Line Interface Unit for

 

Fail

Ports 1–2 (LIU A), 3–4 (LIU B), 5–6

 

 

(LIU C), or 7–8 (LIU D) failed.

 

 

 

 

EEPROM

The unit failed Electrically Erasable

 

Fail

Programmable Read-Only Memory

 

 

verification.

 

 

 

 

Failure

An internal failure occurred.

Record the failure code and

xxxxxxxx

(xxxxxxxx represents an 8-digit

contact your service

 

hexadecimal failure code for use by

representative.

 

service personnel.)

 

 

 

 

FPGA Failed

The Field Programmable Gate Array

1. Reset the unit and try again.

 

serving all ports failed.

2. Call your service

 

 

G.703

The unit failed to loop data on the

representative for assistance.

 

Failed, Pt 1

G.703 on Port n.

 

 

 

 

Memory

The unit failed memory data

 

Test n Fail

verification (Test 1) or memory

 

 

address verification (Test 2).

 

Passed

No errors were detected.

N/A

7-6

April 2000

8700-A2-GB20-00

Page 52
Image 52
Paradyne 8747, 8777, 8779, Hotwire M/SDSL and HDSL2 Termination Units manual Self-Test Results Messages, Call your service