Configuration Options

Table A-7. System Options (2 of 2)

Telco Initiated Loopback

Possible Settings (Models 8747, 8777): Enable, Disable

Default Setting: Enable

Determines if the unit will respond to Telco loopback commands on the DSX-1 interface. See Telco-Initiated Tests in Chapter 8, Testing.

Enable – The unit will respond to Telco loopback commands.

Disable – The unit will not respond to Telco loopback commands.

Remote Telco Line Loopback

Possible Settings (Models 8747, 8777): Enable, Disable

Default Setting: Disable

Determines if the unit will perform a Telco initiated loopback on just the local unit or if the loopback will be performed on the remote DSL unit. See Telco-Initiated Tests in Chapter 8, Testing.

Enable – The loopback will be in the remote unit.

Disable – The loopback will be local.

G.703 Line Termination

Possible Settings (Model 8779): 75 ohms, 120 ohms

Default Setting: 120 ohms

Specifies the impedance of the G.703 interface

75 ohms – The G.703 interface impedance is 75 ohms unbalanced.

120 ohms – The G.703 interface impedance is 120 ohms balanced.

A-12

April 2000

8700-A2-GB20-00

Page 96
Image 96
Paradyne 8747, 8777 Table A-7. System Options 2, Telco Initiated Loopback, Remote Telco Line Loopback, Line Termination