Standards Compliance for

SNMP Traps

B

SNMP Traps

This section describes the unit’s compliance with SNMP standards and any special operational features for the SNMP traps supported. The unit supports the following traps:

HwarmStart

HauthenticationFailure

HlinkUp

HlinkDown

HEnterprise-specific traps

ifIndex

The object ifIndex is a variable binding for several traps. The following ifIndex values are supported for Hotwire 87xx Termination Units:

ifIndex

3–10

15–22

39–46

Description

DSL Interface Ports 1–8

DSX-1 or G.703 Interface Ports 1–8

EOC Management Link Ports 1–8

For a unit defined as an LTU running IP Conservative software or a unit not running IP conservative software, all traps have at a minimum a variable binding of the Overloaded ifIndex (OI). The formula for the OI is:

((LTU Slot Number) * 1,000) + ifIndex.