Configuration Options

Table A-1. Network Interface Options (3 of 3)

Transmit Attenuation

Possible Settings: 0dB, 3dB, 6dB

Default Setting: 0dB

Determines the amount the transmit power of the unit is reduced to accommodate a short line length. 0dB denotes no attenuation.

0dB – The full transmit power is used.

3dB or 6dB – The transmit power is reduced the specified amount.

Peer IP Address (LTU Only)

Possible Settings: 001.000.000.000 – 223.255.255.255, Clear

Default Setting: 000.000.000.000

Specifies the peer IP address providing the remote management link on the DSL loop.

HPeer IP Address is only available when the unit is configured as an LTU and the unit is in not running in IP Conservative mode.

Address Field (001.000.000.000 – 223.255.255.255) – Enter an address for the peer unit. The range for the first byte is 001 to 223, with the exception of 127. The range for the remaining three bytes is 000 to 255. The IP address must be in the same subnet as the MCC backplane address.

Clear – Clears the IP address and sets to all zeros.

DS0 Cross Connect Line Framing (Model 8777, LTU only)

Possible Settings: ESF, D4

Default Setting: ESF

Specifies the framing format to be used at the DSL interface for DS0 cross connects, regardless of the framing format specified for the DSX-1 ports.

HDS0 Cross Connect Line Framing is only available on the Model 8777, only when the unit is configured as an LTU, and only when the port is in a DS0 cross connect.

ESF – ESF framing formatting is used for transmitted and received data over the DSL Interface.

D4 – D4 framing format is used for transmitted and received data over the DSL Interface.

Circuit Identifier

Possible Settings: [ASCII Text]

Default Setting: [blank]

Uniquely identifies the circuit number of the transmission vendor’s DSL line for troubleshooting purposes.

[ASCII Text] – Enter a maximum of 128 characters. All printable ASCII characters except ^ (caret) are allowed.

Clear – Clears the field.