Page 51
Image 51

Monitoring and Troubleshooting

Table 7-1. Health and Status Messages (3 of 3)

Message

What Message Indicates

What To Do

 

 

 

 

NTU TS16 Not

The LTU is configured for

1.

Verify endpoint is a G.703

Supported

TS16 signaling and the NTU

 

product. EIA-530-A products do

 

is not configured to support

 

not support signaling.

 

TS16 signaling.

2.

Replace endpoint or reconfigure

 

 

 

 

 

TS16 to data.

 

 

 

NTU/LTU

The NTU is not configured

Configure units to match.

Mismatch, Pt n

compatibly with the LTU.

 

 

 

 

 

 

OOF at Net, Pt n

An Out Of Frame (OOF)

1.

Check the Transmit Clock Source

 

condition has been detected.

 

configuration options. Do not set

 

An OOF condition is declared

 

both the local and remote unit to

 

when 2 out of 4 frame

 

Internal, External, or Loop timing.

 

synchronization bits are in

2.

Set the unit to run at a lower DSL

 

error.

 

 

line rate.

 

 

 

 

 

3.

Contact network provider.

 

 

 

 

Primary Clock

A failure has occurred in the

1.

Verify that the network cable is

Failed, Pt n

primary clock source for the

 

securely attached at both ends.

 

DSX-1 or G.703 port.

2.

Contact network provider.

 

 

 

 

 

Primary System

A failure has occurred in the

Contact your service representative.

Clock Failed

clock common to all

 

 

 

cross-connect circuitry.

 

 

 

 

 

 

RAI at G.703,

An RAI (Remote Alarm

1.

Check the status of the upstream

Pt n

Indication) signal is being

 

device.

 

received by the G.703

2.

Verify proper NTU and LTU

 

interface.

 

 

configuration.

 

 

 

 

 

 

Secondary

A failure has occurred in the

Contact your service representative.

System Clock

fallback clock for the system

 

 

Failed

clock.

 

 

 

 

 

 

System

There are no problems

 

 

Operational

detected.

 

 

 

 

 

 

Yellow Alarm at

A Yellow Alarm Indication

1.

Verify that the unit’s line framing

DSX-1, Pt n

signal is being received by

 

and line coding are compatible.

 

the DSX-1 interface.

2.

Contact network provider.

 

 

 

 

 

 

8700-A2-GB20-00