Paradyne 8777, 8747, 8779 manual Table A-5. G.703 Interface Options 2, Line Coding

Models: Hotwire M/SDSL and HDSL2 Termination Units 8777 8747 8779

1 167
Download 167 pages 40 Kb
Page 93
Image 93

Configuration Options

Table A-5. G.703 Interface Options (2 of 2)

Line Coding

Possible Settings: AMI, HDB3

Default Setting: HDB3

Specifies the line coding format to be used by the G.703 interface.

AMI – Indicates the line coding format used by the G.703 interface is Alternate Mark Inversion (AMI).

HDB3 – Indicates the line coding format used by the G.703 interface is HDB3.

Line Framing

Possible Settings: CRC4, noCRC4

Default Setting: noCRC4

Specifies the framing format to be used by the G.703 interface.

HLine Framing is only available when the unit is configured as an LTU, AutoRate is disabled, and the DSL Line rate is 2064 kbps. Otherwise the noCRC4 framing format is used. The NTU is automatically configured to match the framing format used by the LTU.

CRC4 – CRC4 framing formatting is used for transmitted and received data over the G.703 Interface.

noCRC4 Non-CRC4 framing format is used for transmitted and received data over the G.703 Interface.

Time Slot 16

Possible Settings: Signaling-CAS, Signaling-CCS, Data

Default Setting: Signaling-CCS

Specifies whether the G.703 interface is used for voice or data.

Signaling-CAS– Time slot 16 contains Channel Associated Signaling (CAS) information (the unit is in voice mode).

Signaling-CCS– Time slot 16 contains Common Channel Signaling (CCS) information (the unit is in voice mode).

Data – Time slot 16 contains data (the unit is in data mode).

Primary Clock Source

Possible Settings: Internal, G.703

Default Setting: Internal

Determines the primary clock source for the unit.

HPrimary Clock Source is available only when the unit is configured as an LTU.

Internal – Timing is derived from the internal oscillator.

G.703 – Timing is derived from the G.703 interface.

8700-A2-GB20-00

April 2000

A-9

Page 93
Image 93
Paradyne 8777, 8747, 8779, Hotwire M/SDSL and HDSL2 Termination Units manual Table A-5. G.703 Interface Options 2, Line Coding