Paradyne Hotwire M/SDSL and HDSL2 Termination Units, 8747, 8777 Table A-7. System Options 1

Models: Hotwire M/SDSL and HDSL2 Termination Units 8777 8747 8779

1 167
Download 167 pages 40 Kb
Page 95
Image 95

Configuration Options

System Options

For System Options, refer to Table A-7. To access the System Options screen, follow this menu selection sequence:

Main Menu Configuration Load Configuration From

main/config/system

 

 

Slot: 18

 

Model: 87xx

SYSTEM OPTIONS

 

 

DSL Mode:

LTU

 

Test Timeout:

Enable

 

Test Duration (min):

10

 

Telco Initiated Loopbacks:

Enable

(Models 8747, 8777)

Remote Telco Line Loopback:

Disabled

(Models 8747, 8777)

G.703 Line Termination

120 Ohm

(Model 8779)

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

Table A-7. System Options (1 of 2)

DSL Mode

Possible Settings: LTU, NTU

Default Setting: LTU

Controls whether the unit is configured as a control unit or tributary unit.

LTU – The unit is configured as a control unit (Line Termination Unit).

NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit will request its IP address from the LTU during establishment of the PPP link.

NOTE: Changing this option will reset the card.

Test Timeout

Possible Settings: Enable, Disable

Default Setting: Enable

Allows tests to end automatically. The feature should be enabled when the unit is remotely managed, so that control can be regained after a test is accidentally executed.

Enable – Loopback and pattern tests end when test duration is reached.

Disable – Tests run until manually terminated from the Network Tests screen or remotely (network initiated tests). Refer to Running Network Tests in Chapter 8, Testing.

Test Duration (min)

Possible Settings: 1–120

Default Setting: 10

Number of minutes for a test to be active before automatically ending.

HTest Duration (min) option appears when Test Timeout is enabled.

1 to 120 – Amount of time in minutes for a test to run before terminating.

8700-A2-GB20-00

April 2000

A-11

Page 95
Image 95
Paradyne Hotwire M/SDSL and HDSL2 Termination Units System Options, Main Menu → Configuration → Load Configuration From →