Initial Startup and Configuration

Disabling AutoRate

The AutoRate function is controlled from the Network Interface Options screen and allows you to enable or disable AutoRate. The AutoRate option is only available if the unit is configured as an LTU. To access the Network Interface screen, follow this menu selection sequence:

Main Menu Configuration

main/config/network

 

Slot: 4

Model: 87xx

Port: 1

 

NETWORK INTERFACE OPTIONS

 

Margin Threshold:

–3db

Excessive Error Rate Threshold: 1E–5

AutoRate

Enable

Max DSL AutoRate

144

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

"Procedure

The AutoRate option defaults to Enable. To disable AutoRate:

1.Position the cursor in the AutoRate field and press the spacebar.

The AutoRate field toggles to Disable and the DSL Line Rate field appears.

2.Enter a DSL Line Rate and press Enter.

Resetting AutoRate

The Reset AutoRate function of the Control branch causes the unit to repeat the AutoRate sequence. The unit attempts to establish the DSL link at the highest rate (or the value of DSL Line Rate, which represents the AutoRate ceiling when AutoRate is enabled). If the link fails, the next lower rate is tried until the link is established.

To access the Reset AutoRate screen, follow this menu selection sequence:

Main Menu Control Reset AutoRate