Paradyne 8747 Viewing System and Test Status, Health and Status SELF-TEST Results Test Status

Models: Hotwire M/SDSL and HDSL2 Termination Units 8777 8747 8779

1 167
Download 167 pages 40 Kb
Page 48
Image 48

Monitoring and Troubleshooting

Viewing System and Test Status

To view System and Test Status information, follow this menu selection sequence:

Main Menu Status

System and Test Status

 

main/status/system

 

 

Slot: 2

 

Model: 87xx

 

SYSTEM AND TEST STATUS

Page 1 of 1

HEALTH AND STATUS

SELF-TEST RESULTS

TEST STATUS

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

LOS at Net, Pt n

CPU Failed

No Test Active

OOF at Net, Pt n

Device Failed

LLB Test Active, Pt n

EER at Net, Pt n

Net DSL Failed, Pt n

RLB Test Active, Pt n

LOS at DSX-1 Pt n

DSX-1 Pt Failed, Pt n

Lamp Test Active

Net Margin Threshold, Pt n

Memory Failed

DLB Test Active, Pt n

Device Failed yyyyyyyy

Passed

 

Download Failed

 

 

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

ESC for previous menu

MainMenu Exit

The System and Test Status screen has three sections:

HHealth and Status – Displays messages in priority order (highest to lowest). Refer to Table 7-1,Health and Status Messages.

HSelf-Test Results – Results of the Diagnostic test run on the device itself. Refer to Table 7-2,Self-Test Results Messages.

HTest Status – Currently active tests. Refer to Table 7-3,Test Status Messages.