Paradyne Hotwire M/SDSL and HDSL2 Termination Units, 8747, 8777, 8779 manual

Models: Hotwire M/SDSL and HDSL2 Termination Units 8777 8747 8779

1 167
Download 167 pages 40 Kb
Page 123
Image 123

Standards Compliance for SNMP Traps

The tests that affect the enterpriseTestStart and enterpriseTestStop traps and the variable bindings depend on the interface. The specific tests and variable bindings are described in the following table:

Interface

enterpriseTestStart/Stop variable bindings

Possible Cause

DSL Network

HifIndex (RFC 1573)

HifAdminStatus (RFC 1573)

HifOperStatus (RFC 1573)

HifType (RFC 1573)

HifTestType (RFC 1573)

The following objects control tests in SNMP-managed devices:

noTest(0) – Stops the test in progress.

testLoopLLB(4) – Initiates a Local Loopback.

testSendMon511(6) – Initiates a Send and Monitor 511 test.

testSendLLBUp(7) – Initiates an LLB Up message to the remote unit.

testSendLLBDown(8) – Initiates an LLB Down message to the remote unit.

HenterpriseTest Start – Any one of the following tests is active on the interface:

Line Loopback

Remote Line Loopback

Send and Monitor 511

HenterpriseTest Stop – No tests currently running on the interface.

DSX-1 or

H ifIndex (RFC 1573)

H enterpriseTest Start – Any

G.703

H ifAdminStatus (RFC 1573)

one of the following tests is

 

active on the interface:

 

 

 

H ifOperStatus (RFC 1573)

– DTE Loopback

 

H ifType (RFC 1573)

– Repeater Loopback

 

H ifTestType (RFC 1573)

– Telco Payload Loopback

 

(DSX-1 only)

 

The following objects control tests

 

H enterpriseTest Stop – No tests

 

in SNMP-managed devices:

 

– noTest(0) – Stops the test in

currently running on the

 

interface.

 

progress.

 

 

 

– testLoopDTLB(3) – Initiates a

 

 

DTE Loopback.

 

 

– testLoopPLB(1) – A

 

 

Telco-initiated Payload

 

 

Loopback is active on the

 

 

interface (DSX-1 only).

 

 

– testLoopRLB(5) – Initiates a

 

 

Remote Loopback.

 

 

 

 

8700-A2-GB20-00

April 2000

B-7

Page 123
Image 123
Paradyne Hotwire M/SDSL and HDSL2 Termination Units, 8747, 8777, 8779 manual