Standards Compliance for SNMP Traps

For a unit defined as an NTU running IP Conservative software, all traps have at a minimum a variable binding of the Super Overloaded ifIndex (SOI). The formula for the SOI is:

((LTU Slot Number) * 1,000,000)

+((LTU DSL Port Number) * 1,000)

+the NTU’s ifIndex.

warmStart

SNMP Trap

Description

Possible Cause

 

 

 

warmStart

The unit has reinitialized

H Reset command.

 

itself.

H Power disruption.

 

The trap is sent after the unit

 

 

 

resets and stabilizes.

 

 

No variable bindings.

 

 

 

 

authenticationFailure

SNMP Trap

Description

Possible Cause

 

 

 

authenticationFailure

Failed attempts to access

Three unsuccessful attempts

 

the unit.

were made to enter a correct

 

Variable bindings:

login/password combination.

 

 

 

H devAuthentication

 

 

FailureIPAddress

 

 

(Health & Status MIB)

 

 

Returns zero if the IP

 

 

address is unknown or the

 

 

failure came from the

 

 

terminal port.

 

 

 

 

B-2

April 2000

8700-A2-GB20-00

Page 118
Image 118
Paradyne 8779, 8747, 8777 manual WarmStart, AuthenticationFailure, Snmp Trap Description Possible Cause