Table A-10. Assign Time Slots Options (1 of 1)

(DSX-1/DSL or G.703/DSL Selection)

Possible Settings (Models 8747, 8777): DSX-1, DSL

Default Setting: DSX-1

Possible Settings (Model 8779): G.703, DSL

Default Setting: G.703

Determines the port whose time slots are displayed. The unit can be configured using the viewpoint of the DSX-1 or G.703 interface, or the DSL network interface.

DSX-1or G.703 – Time slots for the specified DTE port are displayed.

DSL – Time slots for the specified DSL port are displayed.

(Port Type )

Possible Settings (Models 8747, 8777): D, X

Default Setting: D

Possible Settings (Model 8779): D, G (see note)

Default Setting: D

Shows the type of port to which this time slot is connected.

D – The time slot is connected to a DSL port.

G – The time slot is connected to a G.703 port (Model 8779).

X – The time slot is connected to a DSX-1 port (Models 8747, 8777).

(Port Number)

Possible Settings: 1–8

Default Setting: [Blank]

Determines the port to which this time slot is connected.

(Time Slot Number)

Possible Settings (Models 8747, 8777): 1–24

Default Setting: [Blank]

Possible Settings (Model 8779): 1–31

Default Setting: [Blank]

Determines the time slot to which this time slot is connected.

(Data/Voice Selection)

Possible Settings: d, v

Default Setting: d

Determines whether the time slot is dedicated to the transmission of voice or data.

d – The time slot is used for data.

v – The time slot is used for voice.

NOTES:

If a G.703 port is configured for voice, time slot 16 is used for signaling and is not available for cross-connection.