Monitoring and Troubleshooting

Troubleshooting

The Hotwire Termination Unit is designed to provide you with many years of trouble-free service. If a problem occurs, however, refer to Table 7-6 for possible solutions. If an error message is displayed under Health and Status on the System and Test Status screen, refer to Table 7-1,Health and Status Messages, for recommended action.

Table 7-6. Troubleshooting (1 of 2)

Symptom

Possible Cause

Solutions

 

 

 

Alarm LED is on.

A system failure has

Refer to Table 7-1,Health and

 

occurred.

Status Messages, for

 

 

recommended action.

 

 

 

Cannot access the

The terminal is not set up

H Check the cable and

unit via the ATI.

for the correct rate or data

connections.

 

format, or the unit is

H Ensure that the unit is configured

 

configured so it prevents

 

properly in the DSLAM. Verify its

 

access.

 

IP address.

 

 

 

 

H Reset the unit.

 

 

 

Device Fail appears

The unit detects an internal

H Reset the unit.

on the System and

hardware failure.

H Contact your service

Test Status screen

 

 

representative.

under Self-Test

 

 

 

results.

 

 

 

 

 

Power-On Self-Test fails. Only Alarm LED is on after power-on.

The unit has detected an internal hardware failure.

No power, or the

The unit is not properly

Verify that the unit is properly

LEDs are not lit.

seated in the DSLAM.

inserted.

 

 

 

 

There is no power to the

Verify that the DSLAM has power.

 

DSLAM.

 

 

 

 

An LED is not lit.

LED is out.

Run the Lamp Test. If the LED in

 

 

question does not flash with the

 

 

other LEDs, then contact your

 

 

service representative.

 

 

 

Not receiving data.

HThe network or DTE port cables are not connected (check front panel LEDs for more information).

HA test is being executed on the unit (check the TEST LED on the front panel).

HThe far-end device is offline.

HCheck network and DTE port cables.

HCheck Health and Status menu.

HRun Loopback tests. Refer to Chapter 8, Testing.

HStop the test or wait for the test to end.

HMake sure the far-end device is on.