Paradyne 8747, 8777, 8779, Hotwire M/SDSL and HDSL2 Termination Units manual Send and Monitor

Models: Hotwire M/SDSL and HDSL2 Termination Units 8777 8747 8779

1 167
Download 167 pages 40 Kb
Page 76
Image 76

Testing

Send and Monitor 511

The Send and Monitor 511 test causes the local and remote units to send a 511 test pattern to each other. Also, for DSX-1 models, all ones are sent to DSX-1 time slots connected to the DSL port being tested.

The front panel Test LEDs of both units light up during the test. The duration and results of the test are displayed on the Network Test screen to the unit that initiated the test.

NOTE:

The Send and Monitor 511 test is not a loopback test. Each unit independently sends and monitors a 511 pattern.

AIS

LIU

T1/E1

Framer

CAP

Framer

CAP

511

Gen

511

Mon

Transceiver

511

Pattern

511

Pattern

CAP

511

Mon

511

Gen

Transceiver

CAP

Framer

T1/E1

Framer

LIU

DSX-1 AIS or

G.703

Port

99-16616

"Procedure

To run a Send and Monitor 511 test:

1.Position the cursor at the Start command next to Send and Monitor 511 on the Network & DSX-1 or Network & G.703 Tests screen.

2.Press Enter.

The Start command is changed to Stop.

3.To manually stop the test, verify that the cursor is positioned at the Stop command.

4.Press Enter.

When a Send and Monitor 511 test is active, a count of bit errors is displayed next to the test duration, and the ResetMon virtual function key is available for use. Type r or R or select the ResetMon virtual function key to reset the error count.

8-8

April 2000

8700-A2-GB20-00

Page 76
Image 76
Paradyne 8747, 8777, 8779, Hotwire M/SDSL and HDSL2 Termination Units manual Send and Monitor