Monitoring and Troubleshooting

Device Messages

The Device Messages in Table 7-4, listed in alphabetical order, may appear in the messages area at the bottom of the ATI screens.

Table 7-4. Device Messages (1 of 2)

Device Message

What Message Indicates

What To Do

 

 

 

0.0.0.0 is an invalid

An IP address of all zeros

Enter a valid, non-zero IP

IP address

was entered.

address.

 

 

 

Access level is

The operator requested that

If configuration options are to be

Operator.

configuration options be

edited, use a Login ID that has

Configuration is

loaded, but does not have

Administrator authority.

read-only.

authority to edit them.

 

 

 

 

Cannot Save – no

All of the login IDs being

Change the access level of at

Login IDs with Access

saved have an access level

least one Login ID to

Administrator

below Administrator.

Administrator so that

 

 

configuration changes can be

 

 

made. (Operator-level users

 

 

cannot make configuration

 

 

changes.) Save the Login IDs.

 

 

 

Command Complete

Action requested has

No action needed.

 

successfully completed.

 

 

 

 

Invalid Character ( x )

A nonprintable ASCII

Re-enter information using valid

 

character (x) has been

characters.

 

entered.

 

 

 

 

Invalid Password

Login is required and an

H Try again.

 

incorrect password was

H Contact your system

 

entered; access is denied.

 

administrator to verify your

 

 

 

 

password.

 

 

 

Invalid – Send Pattern

A pattern test was already

H Allow test to continue.

Already Active

in progress when the Start

H Select another test.

 

field was selected.

 

 

 

 

H Stop the test.

 

 

 

Invalid – [Test]

The described test was

H Allow test to continue.

Already Active

already in progress when

H Select another test.

 

another selection was

 

 

 

made.

H Stop the test.

 

 

 

Invalid Test

A loopback or pattern test

H Wait until other test ends and

Combination

was in progress when Start

message clears.

 

was selected to start

H Abort all tests from the Test

 

another test, or was active

 

menu screen.

 

on the same or another

 

 

 

interface when Start was

H Stop the test from the same

 

selected.

screen the test was started

 

 

from.

 

 

 

IP address not in MCC

The Peer IP address

Enter an IP address that is in the

subnet

specified is not in the same

same subnet as the MCC.

nnn.nnn.nnn.nnn

subnet as the MCC.

 

 

 

 

7-8

April 2000

8700-A2-GB20-00