Parker Hannifin G2 manual Select a trigger mode

Models: G2

1 189
Download 189 pages 16.5 Kb
Page 109
Image 109
(3)Select a trigger mode.

[How to use the oscilloscope]

(1)Click “Log Start” on the “Oscilloscope” dialog box to display the “SetCondition/ELogStart” dialog box (see Figure 8.19).

2)Source selection choice box

5)Trigger source

3)Trigger mode

6)Trigger level

7) Trigger position

8) Time

4) Trigger edge

9) Set/Start

Figure 8.19 “SetCondition/ELogStart” dialog box

(2)Click the ↓ to select the parameters/monitors you want to display in the “source selection choice box.” (CH1 to CH4)

(3)Select a trigger mode.

Free: Obtains data immediately without using the trigger.

Single: Obtains data when the trigger conditions are met.

(4)Select a trigger edge. (Valid when the trigger mode is Single.)

(5)Click the ↓ to select a trigger source. (Valid when the trigger mode is Single.)

(6)Enter a trigger level. (Valid when the trigger mode is Single.)

(7)Click the ↓ to select a trigger position. (Valid when the trigger mode is Single.)

(8)Click the ↓ to select a time (horizontal axis). (The unit is msec.)

(9)Click “Set/Start” to return to the “Oscilloscope” dialog box and wait for the completion of data acquisition.

(10)When the data is obtained, “Start Acquisition” becomes active.

(11)Click “Start Acquisition” to extract data from the driver and display it in the “Oscilloscope” dialog box.

Note: If the set trigger conditions are not satisfied and “Start Acquisition” does not become active, click “Log Stop” and set the trigger conditions again.

8

8-17

Page 109
Image 109