Parker Hannifin G2 manual Error number

Models: G2

1 189
Download 189 pages 16.5 Kb
Page 185
Image 185

Error number

45

- direction software over-travel

 

 

 

 

Long:

 

 

 

Soft_OT_-_direction

Error type:

[KIND_ERR] error

 

Short:

Measures:

[TYPE_E2] Stop deceleration.

-_Soft_OT

Main cause:

Attempted to move to outside of the - direction area via positioning move, but the command unit

 

command value was outside of the - direction area.

 

Action to take:

Perform an error reset operation. If the command unit command value is outside of the area, move to

 

the + direction. This error occurs only for the linear coordinates.

Error number

46

Emergency stop

 

 

 

 

Long:

 

 

 

EmergencyStop

Error type:

[KIND_RGR] Always error

Short:

Measures:

[TYPE_E2] Stop deceleration.

EMG_Stop

Main cause:

An emergency stop instruction was entered.

 

Action to take:

Reset the error.

 

 

Error number

49

Homing error

 

 

 

 

Long:

 

 

 

OriginError

Error type:

[KIND_ERRALM1] Error/operation alarm

Short:

Measures:

[TYPE_E2] Stop deceleration.

OriginErr

Main cause:

An error occurred during homing operation.

 

 

[Subcode]

 

 

 

1: Locating fixture position problem

 

Action to take:

 

 

 

Error number

50

Cannot execute

 

 

 

 

Long:

 

 

 

CantExec

Error type:

[KIND_ERRALM2] Error/operation alarm

Short:

Measures:

[TYPE_E2] Stop deceleration.

CantExec

Main cause:

Cannot execute.

 

 

 

[Subcode]

 

 

1:Prohibited command

2:Execution in progress

3:Error status

4:Data is being used.

5:Invalid data

6:Access timing

7:Driver mode

8:Invalid program file

9:Nesting overflow

Action to take:

Page 185
Image 185
Parker Hannifin G2 manual Error number