Parker Hannifin G2 manual Analog monitor selection

Models: G2

1 189
Download 189 pages 16.5 Kb
Page 160
Image 160

70

Analog monitor selection

Always

Minimum value:

0

Long:

Maximum value:

5

AnalogMonitorSelect

Initial value:

4

Short:

Unit:

None

A_MonSel

Select the content to be output to the analog monitor.

 

0:

Position deviation [pulse]

 

1: Test operation response [pulse]

 

2: Position command value [pulse]

 

3: Current position value [pulse]

 

4: Position command differential value (command velocity) [pps]

 

5: Current position differential value (current velocity) [pps]

 

71

Axis positioning error monitoring gain (analog monitor)

Always

Minimum value:

0

Long:

Maximum value:

8

PerrMonitorGain

Initial value:

0

Short:

Unit:

None

PerrMon_G

Specify the position deviation monitoring gain of the analog monitor.

 

0: 6.55V / 32768 pulses

 

1: 6.55V / 16384 pulses

 

2: 6.55V / 8192 pulses

 

3: 6.55V / 4096 pulses

 

4: 6.55V / 2048 pulses

 

5: 6.55V / 1024 pulses

 

6: 6.55V / 512 pulses

 

7: 6.55V / 256 pulses

 

8: 6.55V/ 128 pulses

 

72

Test operation monitoring gain (analog monitor)

Always

Minimum value:

0

Long:

Maximum value:

8

TestMonitorGain

Initial value:

0

Short:

Unit:

None

PerrMon_G

Specify the test operation response monitoring gain of the analog monitor.

0:6.55V / 32768 pulses

1:6.55V / 16384 pulses

2:6.55V / 8192 pulses

3:6.55V / 4096 pulses

4:6.55V / 2048 pulses

5:6.55V / 1024 pulses

6:6.55V / 512 pulses

7:6.55V / 256 pulses

8:6.55V/ 128 pulses

Page 160
Image 160
Parker Hannifin G2 manual Analog monitor selection