Parker Hannifin G2 manual 6.1.4 I/O logic setting, Current limit analog input CRNTLMTIN ±

Models: G2

1 189
Download 189 pages 16.5 Kb
Page 79
Image 79
[Current limit analog input] CRNT_LMT_IN ±

[Current limit analog input] CRNT_LMT_IN ±

Current 100% at 10 VDC

CRNT_LMT_IN+

200k

Current 0% at 0 VDC

 

 

 

 

0 to 10VDC

200k

CRNT_LMT_IN-

Controller

6.1.4I/O logic setting

-

+

For the contact input and contact output signals, it is possible to set the physical I/O status and the logical relationship of the driver’s internal signal status in both contact and bit units.

The input signals IN*** are processed via the I/O logical conversion and are then expressed as a logical input signal ***. If the signal status is reached, it is expressed as 1 and if the status is not reached, expressed as 0. A logical output signal *** is expressed as 1 if the status is reached and 0 if the status is not reached. After conversion via the I/O logical setting, it becomes an output signal OUT_***.

The I/O logical settings at the time of shipment from the factory are set to positive logic for all input and output signals. In other words, the internal input and output signals are set to 1 when the corresponding contact points are turned ON. By setting the I/O logical setting for IN_SERVO to negative logic using the PC utility, it is possible to connect a PLC interface in the same state as it was shipped from the factory. As a result, an RS232C interface can be used to confirm basic operations.

Refer to Chapter 8 “DrvGII PC Utility” for a description of how to set the I/O logic.

 

 

 

 

Driver's internal

 

 

 

 

 

processing

 

Logic setting

Bit I/O status

Logic signal

 

 

 

 

Bit input

Processing

 

Logical input

 

 

 

 

 

 

 

by logic

 

Positive logic

0

Status 0

(IN_***)

setting

 

signal (***)

setting

1

Status 1

 

 

 

Logical

Bit output

Processing

 

 

 

 

 

Negative logic

0

Status 1

by logic

 

output signal

setting

 

 

(OUT_***)

setting

 

(***)

1

Status 0

 

 

 

 

 

 

 

 

 

 

 

 

6

6-5

Page 79
Image 79
Parker Hannifin G2 manual 6.1.4 I/O logic setting, Current limit analog input CRNTLMTIN ±