Parker Hannifin G2 manual Parameter Settings Display, Operation Display Pendant, + H O T E r r E n

Models: G2

1 189
Download 189 pages 16.5 Kb
Page 128
Image 128
9.6Parameter Settings Display

9Operation Display Pendant

9.6Parameter Settings Display

This display is for changing the values of parameters.

When you input a parameter number from the keypad, the display shows a prompt for the parameter when comments are being displayed, and the current value of the parameter when data is being displayed.

When data is being displayed, it is possible to move the cursor to the data setting area using the ← and → keys. In the data setting area (sign part), it is possible to reverse the sigh by pressing the – key. In the data setting area (absolute value part), the setting value can be set using the numeric keys as well as the ↑ and ↓ keys. When you press the Return key, the entered data is set as the parameter value of the parameter number (the Return key is accepted only when data is being displayed).

When the data is set, the setting result is displayed. If it is set normally, the display shows “OK!” If it failed to set, the display shows “NG! [ERROR ALARM CODE]”. When you press the f2 DATA key, the display switches to the data display; when you press the numeric keys or the ↑ and ↓ keys, it switches to the comment display.

In the previous example of display 2), the parameter number “50” is entered to display the prompt character string of that parameter/monitor. If the f2 DATA key is pressed here, display 3) appears and displays the current value of the parameter/monitor. Display 4) shows the status in which the cursor is moved and data is input from the keypad. When the Return key is pressed here, the setting result is displayed as in display 5).

If a nonexistent number is entered, both the data and comment displays show the comment in display 6). In addition, if you input a parameter that exists but cannot be written to, the data display (but not the comment display) changes similarly to display 6).

1) Initial display

#001:+HOT_ErrEn -Set- DATA N/P

Cursor

2) Displaying comment

#050: Position bandwidth

-Set- DATA N/P

3) Displaying data

#050: 0000000012 -Set- CMNT N/P

4) Setting data

#050:-0000000018 -Set- CMNT N/P

5) Displaying setting result

#050:NG![ALM62.0 -Set- DATA N/P

6) Displaying comment (when a number does not exist)

 

 

#000:-----------

 

 

 

-Set- DATA N/P

 

 

 

 

 

 

 

(CMNT)

f2

DATA:

Switches display; to the data display

CMNT:

To the comment (prompt) display

f3

N:

To the next display

f7

P:

To the previous display

0 to 9:

Each character is entered.

-:

 

The sign of the data value is reversed if pressed while the

 

 

cursor is at the data setting area (sign part).

Return key:

Sets the input data to the driver.

and key: Moves the cursor in the parameter number setting area and data setting area (absolute value part) to the left or right.

and key:

Increases/decreases the numeric value of the digit

 

indicated by the cursor.

Parameter number

Comment display area

setting area

 

 

 

 

 

 

 

 

 

 

 

 

#

0 0 1

:

+ H O T _ E r r E n

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- S e t -

D A T A

N / P

 

 

 

 

 

 

 

 

 

 

 

Function key content

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

display area

Parameter number

Data setting area

setting area

(sign part)

 

 

Data setting area

 

 

 

 

 

 

 

 

 

(absolute value part)

 

 

 

 

 

 

 

 

 

 

#

0 0 1

:

 

0 0 0 0 0 0 0 0 0 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- S e t -

C M N T

N / P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ H O T _ E r r E nFunction key content

display area

9-6

Page 128
Image 128
Parker Hannifin G2 manual Parameter Settings Display, Operation Display Pendant, + H O T E r r E n