9Operation Display Pendant

9.6Parameter Settings Display

This display is for changing the values of parameters.

When you input a parameter number from the keypad, the display shows a prompt for the parameter when comments are being displayed, and the current value of the parameter when data is being displayed.

When data is being displayed, it is possible to move the cursor to the data setting area using the ← and → keys. In the data setting area (sign part), it is possible to reverse the sigh by pressing the – key. In the data setting area (absolute value part), the setting value can be set using the numeric keys as well as the ↑ and ↓ keys. When you press the Return key, the entered data is set as the parameter value of the parameter number (the Return key is accepted only when data is being displayed).

When the data is set, the setting result is displayed. If it is set normally, the display shows “OK!” If it failed to set, the display shows “NG! [ERROR ALARM CODE]”. When you press the f2 DATA key, the display switches to the data display; when you press the numeric keys or the ↑ and ↓ keys, it switches to the comment display.

In the previous example of display 2), the parameter number “50” is entered to display the prompt character string of that parameter/monitor. If the f2 DATA key is pressed here, display 3) appears and displays the current value of the parameter/monitor. Display 4) shows the status in which the cursor is moved and data is input from the keypad. When the Return key is pressed here, the setting result is displayed as in display 5).

If a nonexistent number is entered, both the data and comment displays show the comment in display 6). In addition, if you input a parameter that exists but cannot be written to, the data display (but not the comment display) changes similarly to display 6).

1) Initial display

#001:+HOT_ErrEn -Set- DATA N/P

Cursor

2) Displaying comment

#050: Position bandwidth

-Set- DATA N/P

3) Displaying data

#050: 0000000012 -Set- CMNT N/P

4) Setting data

#050:-0000000018 -Set- CMNT N/P

5) Displaying setting result

#050:NG![ALM62.0 -Set- DATA N/P

6) Displaying comment (when a number does not exist)

 

 

#000:-----------

 

 

 

-Set- DATA N/P

 

 

 

 

 

 

 

(CMNT)

f2

DATA:

Switches display; to the data display

CMNT:

To the comment (prompt) display

f3

N:

To the next display

f7

P:

To the previous display

0 to 9:

Each character is entered.

-:

 

The sign of the data value is reversed if pressed while the

 

 

cursor is at the data setting area (sign part).

Return key:

Sets the input data to the driver.

and key: Moves the cursor in the parameter number setting area and data setting area (absolute value part) to the left or right.

and key:

Increases/decreases the numeric value of the digit

 

indicated by the cursor.

Parameter number

Comment display area

setting area

 

 

 

 

 

 

 

 

 

 

 

 

#

0 0 1

:

+ H O T _ E r r E n

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- S e t -

D A T A

N / P

 

 

 

 

 

 

 

 

 

 

 

Function key content

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

display area

Parameter number

Data setting area

setting area

(sign part)

 

 

Data setting area

 

 

 

 

 

 

 

 

 

(absolute value part)

 

 

 

 

 

 

 

 

 

 

#

0 0 1

:

 

0 0 0 0 0 0 0 0 0 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- S e t -

C M N T

N / P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function key content

display area

9-6

Page 128
Image 128
Parker Hannifin G2 manual Parameter Settings Display

G2 specifications

Parker Hannifin G2 is a state-of-the-art platform designed to transform the way industries approach fluid and motion control. As a leader in motion and control technologies, Parker Hannifin has integrated cutting-edge features into the G2, making it a standout choice for various applications, including aerospace, industrial automation, and hydraulic systems.

One of the main features of the Parker Hannifin G2 series is its modular design. This allows users to customize the configuration according to their specific needs, facilitating enhanced versatility and efficiency. The modular approach supports different valve and actuator options, enabling seamless integration with existing systems and allowing for future expansions.

The G2 is equipped with advanced connectivity options, including Ethernet and fieldbus solutions. These technologies enable real-time data exchange and remote monitoring, ensuring optimized performance and reduced downtime. Users can leverage this connectivity to implement preventive maintenance strategies, thereby increasing the overall reliability of their operations.

Another notable characteristic of the G2 platform is its intelligent control algorithms. These algorithms allow for enhanced process automation, ensuring that systems can adapt dynamically to changing operating conditions. The result is improved energy efficiency and lower operational costs, critical factors in today’s competitive market.

Durability is a key aspect of the G2 series as well. Constructed with high-quality materials, the platform is designed to withstand harsh industrial environments, making it ideal for applications where reliability is paramount. Additionally, its compact footprint enables easy installation and integration into existing setups without requiring extensive modifications.

The user interface of the G2 is exceptionally user-friendly. With intuitive design and advanced graphical displays, operators can easily access performance data, diagnostics, and system parameters. This ease of use not only improves operational efficiency but also enhances training processes for new personnel.

In summary, Parker Hannifin G2 represents a significant advancement in fluid and motion control technology. Its modular design, advanced connectivity, intelligent control algorithms, durability, and user-friendly interface make it a compelling choice for industries seeking to enhance their operations. With these features, the G2 empowers businesses to achieve their efficiency, reliability, and performance goals.