POWER MONITORING FUNCTIONS

 

 

 

P89LPC906/907/908

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PCONA

 

7

6

5

 

4

3

 

2

1

0

 

 

Address: B5H

 

 

 

 

 

Not bit addressable

 

RTCPD

-

VCPD

 

-

-

 

-

 

SPD

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset Source(s): Any reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset Value: 00000000B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIT

SYMBOL

FUNCTION

 

 

 

 

 

 

 

 

 

 

 

 

PCONA.7

RTCPD

Real-time Clock Power down: When ’1’, the internal clock to the Real-time Clock is

 

 

disabled.

 

 

 

 

 

 

 

 

 

 

 

 

PCONA.6

-

Not used. Reserved for future use.

 

 

 

 

 

 

 

 

 

PCONA.5

VCPD

Analog Voltage Comparator Power down: When ’1’, the voltage comparator is powered

 

 

down. User must disable the voltage comparator prior to setting this bit.

 

 

 

PCONA.4

-

Not used. Reserved for future use.

 

 

 

 

 

 

 

 

 

PCONA.3

-

Not used. Reserved for future use.

 

 

 

 

 

 

 

 

 

PCONA.2

-

Not used. Reserved for future use.

 

 

 

 

 

 

 

 

 

PCONA.1

SPD

Serial Port (UART) Power down: When ’1’, the internal clock to the UART is disabled. Note

 

 

that in either Power down mode or Total Power down mode, the UART clock will be

 

 

disabled regardless of this bit (P89LPC907,P89LPC908).

 

 

 

 

 

 

PCONA.0

-

Not used. Reserved for future use.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 7-2: Power Control Register (PCONA)