Chapter 5 - System Maintenance

Fan Replacement for the MGC+50

The fans are not hot swappable and cannot be replaced with the system running. Fans are located on the rear pane of the MGC+50. Use the following procedure to replace a faulty fan:

1.Exit the MGC+ Manager application, turn off the MCU and unplug it from the AC outlet.

2.Using a standard Phillips screwdriver, remove six spring-loaded screws from the fans cover on the MCU’s rear panel.

Lower the fans cover carefully without tearing the cables to gain access to its inner side.

3.Disconnect the two connectors of the power supply cable from the inside of the fan panel. At this point, the fan panel is loose and it may be removed.

4.From the inside of the fan panel, push the connector panel mount locks of the faulty fan connector and push the connector to the front of the panel.

5.Unscrew the four screws on the Fans front panel that secure the faulty fan to the fan panel.

5-16

Page 148
Image 148
Polycom DOC2238A manual Fan Replacement for the MGC+50