MGC+ Hardware and Installation Manual

Table 5-1: Front Panel LEDs

Module

Name

Color

Description

 

 

 

 

Functional

Stby

Green

On during normal operation

Modules

 

 

(refer to Table 5-2)

(Audio+,

Fail

Red

On when a failure has occurred

Video+, IP+,

 

 

(refer to Table 5-2)

MUX+ , MPI and

 

 

Active

Yellow

On when the module is handling

T-120)

 

 

a conference (refer to Table 5-2)

 

 

 

 

 

 

 

Net-2 (ISDN and

Line 1

Off

Span x is not in use

T1-CAS)

Line 2

Green

Span x is OK

Network

 

Yellow

Span x yellow alarm (RAI)

Interface

 

 

Red

Span x red alarm (LOS)

Module

 

(additional

 

 

 

LEDs)

 

 

 

 

 

 

 

Net-4 (ISDN and

Line 1

Off

Span x is not in use

T1-CAS)

Line 2

Green

Span x is OK

Network

Line 3

Yellow

Span x yellow alarm (RAI)

Interface

Line 4

Red

Span x red alarm (LOS)

Module

 

(additional

 

 

 

LEDs)

 

 

 

 

 

 

 

Net-8 (ISDN and

Line 1

Off

Span x is not in use

T1-CAS)

Line 2

Green

Span x is OK

Network

Line 3

Yellow

Span x yellow alarm (RAI)

Interface

Line 4

Red

Span x red alarm (LOS)

Module

Line 5

(additional

 

 

Line 6

 

 

LEDs)

 

 

Line 7

 

 

 

 

 

 

Line 8

 

 

 

 

 

 

Power Supply

In

Green

Power-in from the mains is OK.

Module

Out

 

 

 

 

 

 

5-5