MGC+ Hardware and Installation Manual

PORTS

PORTS

1-4

9-12

PORTS

PORTS

5-8

13-16

MPI-8 MPI-8

A A

B B

10.Connect the serial cable running from the DCE to the appropriate 37-pin connector on the rear panel of the MPI Box. If dialing is used, connect the appropriate cable from the DCE to the 25-pin connector on the rear panel of the MPI Box.

Whenever the MGC+ unit is used as a DCE and connected straight to an endpoint the serial data stream flows from the endpoint (DTE) through the serial connector to the MPI box. The connections stay the same, meaning; the endpoint is connected to the back of the MPI box by way of the 37-pin connector, and the other side of the MPI box is then connected by way of the 160-pin connector to the MPI card in the MGC+ unit.

If V.35 or RS-530 cable is used, attach the special adapter (provided with the kit) to the 37-pin prior to connecting the serial cable from the DCE.

The serial (MPI) network properties must be defined in the Network Services, For details, see MGC+ Administrator’s Guide, Chapter 3.