VTrak M-Class Product Manual

Battery LED Fan 1 LED Fan 2 LED

Figure 8. Battery and fan LEDs VTrak M300f/i/p and M200f/i/p

Under normal conditions, the power supply, battery, and fan LEDs should display green. Note that on the VTrak M-Class, the left cooling unit houses a cache- backup battery but the right unit does not.

LEDs

 

 

State

 

 

 

 

 

 

 

Dark

Green

 

Amber

Red

 

 

 

 

 

 

Power supply

Not detected

OK

 

Fan failed

Failed

 

 

 

 

 

 

Battery

Not detected

OK

 

Too hot or

Failed

 

 

 

 

Low capacity

 

 

 

 

 

 

 

Fan 1 or 2

Not detected

OK

 

Wrong speed

Failed

 

 

 

 

 

 

To check a component’s installation, follow the same procedure as replacing the component, except that you reinstall the original component rather than a new one. In most cases, this action fixes a bad connection and allows VTrak to detect the component. If this action does not correct the problem, replace the unit. See page 215 for instructions.

The Controller Location LEDs, on the back of the VTrak subsystem, will flash for one minute.

Status LED

Dirty Cache LED

Figure 9. A VTrak Fibre Channel controller

266

Page 274
Image 274