VTrak M-Class Product Manual

Overheating

Overheating is a potentially serious condition because the excessively high temperatures can lead to disk drive failure and controller malfunction.

Overheating usually results from:

Fan failure

Poor air circulation around the enclosure

WebPAM PROe reports failed fans along with elevated temperature. On VTrak, there are two kinds of fans:

Power supply, 1 fan each, 2 fans total

Cooling units, 2 fans each

If a power supply fan fails, you must replace the power supply. If a cooling unit fan fails, you can remove the cooling unit and replace only the fan itself.

No tools are required for either procedure. See page 221 for instructions on replacing the fans.

Air circulation around the VTrak enclosure may be a more complex problem. Use the thermometer icons to help you locate the specific hot spot. Check for these conditions:

Accumulated dust or objects blocking the fans

Less than a minimum of 5 inches (13 cm) space between the back of the VTrak and the wall or other object

Ambient temperature above 95°F (35°C) where the VTrak is operating

To cool down a VTrak, do the following:

Correct any problems identified above

Power it down and let it sit for an hour or longer

290

Page 298
Image 298
Promise Technology M500f, M500i, M300p, M500p, M300i, M300f, M200i, M200p, M200f manual Overheating