Promise Technology M500f Set Up Network Cable Connections, Fibre Channel Storage Area Network

Models: M500i M200f M300f M200p M500p M300p M200i M500f M300i

1 322
Download 322 pages 2.01 Kb
Page 28
Image 28

VTrak M-Class Product Manual

Set Up Network Cable Connections

The VTrak M500f, M300f, and M200f share the same RAID controller design and use Fibre Channel (FC) connections for the data ports.

The VTrak M500i, M300i, and M200i share the same RAID controller design and use iSCSI connections for the data ports.

You can configure your VTrak data connections for a:

Storage Area Network (SAN)

Direct Attached Storage (DAS)

The VTrak M500p, M300p, and M200p share the same RAID controller design and use SCSI connections for the data ports. SCSI is limited to a DAS solution.

All VTrak models in this series have a single Ethernet (RJ-45) Management Port. connector that enables you to monitor the VTrak over your network using the WebPAM PROe Software. VTrak supports Ethernet and Telnet protocols.

Fibre Channel Storage Area Network.

 

Network Switch

 

 

FC Switch

 

 

Management

 

 

Port

 

 

 

Controller

 

 

VTrak

PC

FC HBA Card

FC Port (1 of 2)

NIC

Figure 8. VTrak M500f SAN connections (M300f and M200f are similar)

This arrangement requires:

A Fibre Channel switch

A Fibre Channel HBA card in the Host PC

20

Page 28
Image 28
Promise Technology M500f, M500i, M300p, M500p, M300i Set Up Network Cable Connections, Fibre Channel Storage Area Network