Promise Technology M300p, M500i, M500f, M500p, M300i, M300f, M200i, M200p, M200f Power Supplies, Battery

Models: M500i M200f M300f M200p M500p M300p M200i M500f M300i

1 322
Download 322 pages 2.01 Kb
Page 299
Image 299

Chapter 8: Troubleshooting

Power Supplies

VTraks are equipped with redundant power supplies. The advantage of dual power supplies is that, should one fail, the other will continue powering the subsystem until the faulty one can be replaced. VTrak is capable of operating on a single power supply. As a result, if one power supply fails you must watch the front panel LEDs or WebPAM PROe in order to become aware of the condition.

The power supplies are hot-swappable, meaning you can leave the VTrak running when you replace the bad one. Be careful, however, to remove the faulty power supply and not the good one, or VTrak will come to an immediate stop and your data will be unavailable until the system is powered and booted again.

As noted above, if a power supply fan fails, you must replace the power supply. Without the fan to cool it, the power supply will overheat and eventually fail anyway.

No tools are required for the procedure. See your page 220 for instructions on replacing a power supply.

Battery

VTrak uses a battery as backup power for the cache. Should a power failure occur, the battery enables the cache to hold data up to 72 hours. The battery recharges during normal VTrak operation.

In most cases, installing a replacement battery will correct a marginal or failed condition. The battery is located on the left cooling unit. Remove the cooling unit for access. The battery is hot-swappable.

No tools are required for the procedure. See page 230 for instructions on replacing the battery.

291

Page 299
Image 299
Promise Technology M300p, M500i, M500f, M500p, M300i, M300f, M200i, M200p, M200f manual Power Supplies, Battery