Promise Technology M500p, M500i, M500f, M300p, M300i, M300f, M200i Replace Power Supply All Models

Models: M500i M200f M300f M200p M500p M300p M200i M500f M300i

1 322
Download 322 pages 2.01 Kb
Page 228
Image 228

VTrak M-Class Product Manual

3.Press the spacebar to display Restart then press Enter. A warning message appears.

4.Press Y to continue.

The screen will display shutdown and startup functions.

5.When the Login: prompt appears, log into the CLU again.

Replace Power Supply – All Models

Figure 6. The VTrak M500f/i/p power supply shown above.The M300f/i/p and M200f/i/p are similar

The power supply and its fan are replaced as one unit. There are no individually serviceable parts. No tools are required for this procedure.

To remove the power supply, do the following:

1.Verify that the power supply LED is amber or red.

2.Switch off the power.

3.Unplug the power cord.

4.Press the release button and pull the handle downward as shown (above, left).

5.Pull the power supply out of the VTrak enclosure (above, center).

To install the power supply, do the following:

1.Carefully slide the power supply into the enclosure.

2.Gently press the handle in and upward until it locks (above, right).

3.Plug in the power cord.

4.Switch on the power supply.

5.Verify that the new power supply LED is green.

This completes the power supply replacement procedure.

220

Page 228
Image 228
Promise Technology M500p, M500i, M500f, M300p, M300i, M300f, M200i, M200p, M200f manual Replace Power Supply All Models