VTrak M-Class Product Manual

Event

Action

 

 

Drive-interface controller

Restart the VTrak. See page 218. If this message

is NOT found

appears repeatedly, contact Technical Support. See

 

page 299.

 

 

Drive-interface

Normal.

diagnostics has passed

 

 

 

Drive-interface

Restart the VTrak. See page 218. If this message

diagnostics has failed

appears repeatedly, contact Technical Support. See

 

page 299.

 

 

Drive-interface controller

Drive-to-controller parity error. If this message

has generated a general/

appears repeatedly, contact Technical Support. See

data parity error.

page 299.

 

 

Enclosure

 

 

 

Enclosure temperature is

The VTrak is overheating. Check for airflow around

above the threshold/

and through the VTrak, and verify that all fans are

warning threshold

working. Replace fans as needed.

 

 

Enclosure temperature is

The VTrak is seriously overheating. Check for airflow

above the critical

around and through the VTrak, and verify that all fans

threshold

are working. Replace fans as needed.

 

 

Enclosure temperature is

Normal.

within the normal range

 

 

 

Event Log

 

 

 

Event logging is enabled

Event logging has been successfully enabled.

 

 

Event logging is disabled

Event logging has been disabled.

 

 

Event log buffer is cleared

The event log was cleared.

in RAM

 

 

 

Event log buffer is cleared

The non-volatile RAM event log was cleared.

in NVRAM

 

 

 

Event log buffer is cleared

The MDD (disk drive) event log was cleared.

in MDD

 

 

 

Host Interface Controller

 

 

 

Host-interface controller

A FC/iSCSI error occurred. If this message appears

has detected parity/data

repeatedly, contact Technical Support. See

parity/command parity

page 299.

error

 

 

 

274

Page 282
Image 282
Promise Technology M500p, M500i, M500f, M300p, M300i, M300f, M200i, M200p, M200f Enclosure, Event Log, Host Interface Controller