VTrak M-Class Product Manual

Read Community – Type a community name in this field

Write Community – private (no change possible)

4.Press Ctrl-A to save your settings.

To start, stop or restart the SNMP service, highlight Start, Stop, or Restart and press Enter.

SNMP Trap Sinks

1.Highlight SNMP and press Enter.

2.Highlight Trap Sinks and press Enter. A list of the current trap sinks appears.

To add a trap sink:

1.Highlight Create New Trap Sink and press Enter

2.Highlight Trap Sink IP address and press the backspace key to erase the current value, then type the new IP address in this field.

3.Highlight Trap Filter and press the spacebar to toggle through the severity levels.

The Severity Levels are (lowest to highest) Information, Warning, Minor, Major, Critical and Fatal.

4.Press Ctrl-A to save the Trap Sink.

To delete a trap sink:

1.Highlight the trap sink you want to delete and press the spacebar to mark it. The mark is an asterisk (*) to the left of the listing.

2.Highlight Delete Marked Entries and press Enter.

CIM

1.Highlight CIM and press Enter.

2.Highlight Startup Type and press the spacebar to toggle between Automatic and Manual.

3.Highlight HTTP and press the spacebar to toggle between Enabled and Disabled.

4.Highlight HTTP Port, press the backspace key to erase, type new value. 5988 is the default port number.

5.Highlight HTTPS and press the spacebar to toggle between Enabled and Disabled.

6.Highlight HTTPS Port, press the backspace key to erase, type new value. 5989 is the default port number.

7.Highlight Authentication and press the spacebar to toggle between Enabled and Disabled.