Chapter 7: Technology Background

From

To

Increase

 

Redundancy

 

 

 

 

 

Capacity

Performance

Add

Lose

 

 

 

 

 

 

 

 

 

RAID 5

RAID 50

 

 

 

•*

 

 

 

 

 

 

 

 

 

RAID 10

 

 

 

 

 

 

 

 

 

 

 

 

RAID 0

 

 

 

 

 

 

 

 

 

RAID 1/1E

RAID 50

 

 

 

 

 

 

 

 

 

 

 

RAID 10

 

 

 

 

 

 

 

 

 

 

 

RAID 5

 

 

 

 

 

 

 

 

 

 

 

RAID 0

 

 

 

 

 

 

 

 

 

RAID 0

RAID 50

 

 

 

 

 

 

 

 

 

 

RAID 10

 

 

 

 

 

 

 

 

 

 

RAID 5

 

 

 

 

 

 

 

 

 

 

RAID 1/1E

 

 

 

 

 

 

 

 

 

 

 

* Increases the existing redundancy

Important

The Target disk array may require more disk drives than the Source disk array

If the Target disk array requires an EVEN number of disk drives but the Source disk array has an ODD number, ADD a disk drive as part of the migration process

You cannot reduce the number of disk drives in your disk array, even if the Target disk array requires fewer disk drives than the Source disk array

RAID 1 (mirroring) works with two drives only. Only a single- drive RAID 0 disk array or a single-drive JBOD can migrate to RAID 1. Other RAID Levels use too many drives to migrate

You cannot migrate a disk array when it is Critical or performing activities such as Synchronizing, Rebuilding, and

PDM

255

Page 263
Image 263
Promise Technology M300p, M500i, M500f, M500p, M300i, M300f, M200i, M200p, M200f manual RAID RAID 1/1E