Chapter 4—Front panel display and meter setup

PowerLogic™ PM5300 series user guide

 

 

protected prevents unauthorized personnel from accessing certain screens such as the diagnostics and reset screens.

NOTICE

LOST DATA

Record your meter's screen password information in a secure location.

Failure to follow these instructions can result in data loss.

If you lose your password, you must return the meter for factory reconfiguration, which resets your device to its factory defaults and destroys all logged data.

Password setup menu tree

Maint

Reset

Meter

 

 

Setup

Comm

 

 

 

Alarm

 

 

 

I/O

Displ

 

 

HMI

Region

 

 

Clock

Pass

1.Navigate to Maint > Setup.

2.Enter the setup password (default is “0000”), then press OK.

3.Navigate to HMI > Pass.

4.Move the cursor to point to the parameter you want to modify, then press Edit.

5.Modify the parameter as required, then press OK.

6.Move the cursor to point to the next parameter you want to modify, press Edit, make your changes, then press OK.

Password setup parameters

Parameter

Values

Description

 

 

 

Setup

0000 - 9999

Sets the password for accessing the meter setup

screens (Maint > Setup).

 

 

Energy Resets

0000 - 9999

Sets the password for resetting the meter’s

accumulated energy values.

 

 

Demand Resets

0000 - 9999

Sets the password for resetting the meter’s

recorded peak demand values.

 

 

Min/Max Resets

0000 - 9999

Sets the password for resetting the meter’s

recorded minimum and maximum values.

 

 

Diagnostics

0000 - 9999

Sets the password for accessing the meter’s

diagnostics screens.

 

 

7. Press to exit. Press Yes to save your changes.

Lost password

If you lose your password, contact technical support for instructions on how to return your meter for factory reconfiguration.

Global-PMC-Tech-support@schneider-electric.com

(00) + 1 (250) 544-3010

NOTE: Be sure to include your meter’s serial number in your e-mail or have it readily available when calling technical support.