4 Chaper Tips Operation
Basic Operation Procedure
8 Drop out the automation data using one of the following methods.
•Touch the MASTER DROP IN button on the window to turn its color to dark red.
•Touch the numerical value of the items subject to automation.
•Release the fader.
•Stop the tape recorder.
Automation data for the items set in WRITE mode in step 6 is written.
Notes
•If a lot of items are dropped in/out at the same time using the MASTER DROP IN button, data near the drop in/drop out point may not be stored and recalled correctly.
•Automation items in WRITE mode are removed from snapshot recall and control from MIDI.
Updating automation data
The data of the automation items is recalled according to the timecode entered. To update automation data, set the desired automation items to READY, then drop them into WRITE.
You can select either ABS mode or TRIM mode to update data, using the ABS button or TRIM button of the TC AUTOMATION buttons on the Automation panel.
In ABS mode, you can set the speed to return to the previous data from the new data in the AUTO RETURN TIME section in the AUTOMATION window.
Fader operation and its results
The following figures show the fader operation and the results | In the figures, the fader operations are indicated using the | ||
of the fader operation. | following lines: | ||
|
|
| : Indicates the data stored last time (previous data) |
|
| ||
When operating the faders in ABS mode |
|
| : Indicates the actual resuts of the fader operation |
|
| ||
|
| (new data). |
Manupulating | Data stored the last time |
the fader |
When operating the faders in trim mode
Manupulating | Data stored the last time |
the fader |
BUTT: The fader is reset to the position stored the last time (previous data) at the instant you release the fader.
RAMP: The fader is reset to the stored position at the specified speed, when you release the fader.
HOLD TO NEXT: After you release the fader, the fader’s position remains as it is up to the next event.
HOLD TO END: After you release the fader, the fader’s position remains as it is up to the end. The previous data is overwritten.
The operation performed while holding the fader down is added to the last stored data as offset and recalling is continued.
100 Chapter 4 Operation Tips