1DYNAMICS IN button
Press this button to make the dynamics section active. The settings on the DYNAMICS section are displayed on the DYNAMICS window (page 47).
2Dynamics access section
Selects the functions of dynamics parameter section 4.
ACCESS button for EXPAND/GATE: Press this button so that the corresponding DYNAMICS window opens. Parameters of the expander and gate can be set using the THRESHOLD, RATIO, ATTACK, HOLD, RANGE/GAIN and RELEASE controls in the Dynamics Parameter section.
IN button for EXPAND/GATE: Press this button to activate the expander and gate.
ACCESS button for COMPRESS/DUCK: Press this button so that the corresponding DYNAMICS window opens. Parameters of the compressor and ducking can be set using the THRESHOLD, RATIO, ATTACK, HOLD, RANGE/GAIN and RELEASE controls in the dynamics parameter section.
IN button for COMPRESS/DUCK: Press this button to activate the compressor ducking function.
Buttons in this section are not used for automation function.
3Dynamics insertion point buttons
Select the point where the dynamics is inserted.
PRE EQ button: Inserts the dynamics settings before the equalizer.
POST EQ button: Inserts the dynamics settings after the equalizer.
PRE EQ and POST EQ buttons are controlled by snapshot automation but not dynamic automation.
4Dynamics parameter section
The function of these buttons in this section depends on the setting of the ACCESS button in the dynamics access section 2.
When the ACCESS button of EXPAND/GATE in the dynamics access section 2 is pressed: the following parameters for the expander and gate can be set. THRESHOLD control: Threshold
RATIO control: Ratio
ATTACK control: Attack time
HOLD control: Hold time
RANGE/GAIN control: Range
RELEASE control: Release time
When the ACCESS button for COMPRESS/DUCK in the dynamics access section 2 is pressed: The following parameters for the compressor and ducking can be set.
THRESHOLD control: Threshold
RATIO control: Ratio (effective only in the COMPRESS mode)
ATTACK control: Attack time
HOLD control: Hold time
RANGE/GAIN control: Range in the DUCK mode and gain in COMPRESS mode.
The fully clockwise position is “AUTO” and results in automatic gain control (when the input signal is
RELEASE control: Release time
Controls and buttons in this section are used for the snapshot and dynamic automation.
2 Chapter
and Locations
of Functions
and Parts
Controls