DYNAMICS Window
To open this window, touch the CHANNEL button on the bottom menu bar, then select “DYNAMICS”. Or when the CHANNEL window is displayed, touch any point of the DYNAMICS display.
This window displays the settings of the DYNAMICS section on the Parameter Setting panel. If you touch the display window where the numerical value is displayed, that item is set to READY status or automation DROP IN/OUT.
1Gain reduction meter
2Dynamics characteristics
3Parameter display section
4Function selectors
5 DYNAMICS IN button
6 INSERTION POINT section
qa KNEE button qs Function access buttons
0 LINK button
9 GATE/DUCK button
8 EXP/COMPRESSOR button
7 KEY button
3 Chapter Menu
1Gain reduction meter
Displays the gain reduction of both dynamics sections.
2Dynamics characteristics
Displays the graph of the dynamics gain transfer function.
3Parameter display section
Displays the following values of the Expander/Gate or Compressor/Ducking selected by the Function selectors 4.
•THRESHOLD: Threshold
•RATIO: Ratio
•ATTACK: Attack time
•HOLD: Hold time
•RANGE: Range of the gate (In compressor mode, gain )
•RELEASE: Release time
Chapter 3 Menu 47