Menu Windows

MISC SETUP Window

To open this window, touch the SYSTEM button on the bottom menu bar, then select “MISC SETUP” on the menu.

This window allows you to control and check settings for the system’s clock, the channel meter display, the sensitivity of the touch sensor and the dimmer level of the monitor signals.

1 DATE/TIME section

3 Chapter

Menu

2CHANNEL METERS section

3 MTR BUS MODE section

4 TOUCH SENSOR section

5 TOUCH PANEL section

6 DIM LEVEL section

1DATE/TIME section Sets the built-in clock.

YEAR MONTH DAY

HOUR (24-hour time display system)

MINUTE SECOND

v/V buttons: Increases or decreases the value.

SET button: Touch this button to adjust the time of the built-in clock.

2CHANNEL METERS section

Sets the peakhold of the master meter and channel meters and selects the signal which is to be displayed on the channel meters.

When the channel faders are used as faders for AUX SEND 1 to 8 or MTR bus, the meters display the level of the bus signal.

METERING POINT button

Selects the point in the signal path to be displayed. INPUT button: Selects the signal of the point just before the switch (phase inversion) of the input signal path.

PRE (prefader) button: Selects the signal of the point located before the CUT switch of the input signal path.

84 Chapter 3 Menu