The maximum value of the programmable delay amount is half.

The channel number of the EXT inputs of MONITOR is reduced from 6 to 2.

When INPUT is selected in the CHANNEL METERS section in the MISC SETUP window, the OVER indicator does not function.

The SOLO buttons of the AUX Return function as AFL buttons even if these are set to PFL.

When SYNC LOCK is set to WORD/DI, if the sync reference signal is greater than 96 kHz, the DSP (Digital Signal Processor) does not work properly and this may cause noise.

2SYNC CLOCK section

AINTERNAL button

BVIDEO button

CWORD/DI button

D Word clock selector

The unit synchronizes using the reference selected by touching one of these buttons.

AINTERNAL button

Touch this button to use the built-in word clock generator as the reference signal.

When this button is selected, external digital audio equipment must be synchronized with the DMX-R100 that is the sync master.

BVIDEO button

The unit synchronizes using the video signal connected to the REF VIDEO connector on the unit. When this button is selected, external digital audio equipment must be synchronized either to the same video signal or to a synchronous word clock, as produced by the mixer.

CWORD/DI (digital input) button

The unit synchronizes using a word clock signal connected to the REF WORD connector or a digital audio signal connected to any of the mixer’ digital inputs. You can select which signal you use as the reference signal by using the word clock selector D. When this button is selected, the unit and external digital audio equipment must be synchronized using the same reference sync signal.

DWord clock selector

Displays the source of the external reference word clock when the WORD/DI button C is touched. Touching the selector results in opening the list and you can then select the source from the following.

REF WORD IN

2TR IN 2

AUX RTN 5/6, 7/8

CH 1/2, CH3/4, CH5/8 or CH7/8 for SLOT 1 to SLOT 4

3PLL status display section

AVIDEO PLL status

BMAIN PLL status

AVIDEO PLL status

When the VIDEO is selected as the reference signal, the status of PLL which generates the word clock signal from the video signal is displayed.

When a signal other than VIDEO is used as the reference signal, “– – – – –” is displayed. LOCK: Operating correctly.

UNLOCK: Synchronization is lost. Check the setting of the terminated resistor or whether the correct video signal is being inputted.

NO VIDEO: The video signal is not input. Check the setting of the terminated resistor or whether the correct video signal is inputted.

– – – –:A signal other than VIDEO is used.