PST (post fader) button: Selects the signal of the point located before the pan of the input signal path. For AUX send, MTR bus and PGM, the signal after the master fader is selected.

PEAK HOLD button

Selects the method used to display the peak hold level of the input signals.

MAN (manual) button: Touch this button to always display the maximum level of the input signal (peakhold status). Touch this button again to cancel the display of the peakhold status.

AUTO button: Touch this button to display the peak level of the input signal for three seconds, and the hold display is automatically reset.

3MTR BUS MODE section

Touch the button to display SURROUND. When SURROUND is displayed, the MTR bus is set to surround mode. When the display is off, the MTR bus is set to mono/stereo mode.

4TOUCH SENSOR section

Sets the sensitivity of the fader touch sensor. SENSITIVITY display: Displays the sensitivity as steps of 0 to 15. The maximum sensitivity is 15. v/V buttons: Increase or decrease the sensitivity. KEEP button: Touch this button to store the sensitivity on the SENSITIVITY display window in the current title. At the same time, data in the work area is also stored in the current title.

5TOUCH PANEL section Calibrates the touch panel.

When the cursor does not move correctly, calibration of the touch panel is required.

Touch the button to open the calibration window.

To calibrate the touch panel, proceed as follows:

1 Turn off the power and connect a mouse to the MOUSE connector on the rear panel. Then turn on the power again.

2 Select the CALIBRATE button on the TOUCH PANEL section.

A dialog box appears.

3 Select [YES] on the dialog box. The calibration window appears.

4 Touch the CALIBRATE button on the window. Perform the following operations, step 5 to step 7, according to the blue arrow indicated on the calibration window.

5 Touch the left top of the window according to the blue arrow indication.

The blue arrow indication turns red. By touching the left top again, the arrow turns blue and points to the right bottom.

Note

The arrow indicates the corner to be touched. Be careful not to touch the arrow itself. If you touch the arrow accidentally, start the calibration operation again from step 1.

6 Touch the right bottom on the window according to the blue arrow indicator.

Touching the arrow at the first time causes the blue arrow to turn red. Touching the red arrow causes a circle mark to appear at a point a little to the right of the center.

Note

Be careful not to touch the arrow.

7 Touch the circle mark on the window.

8 Touch the EXIT button to terminate the calibration.

The calibration of the touch panel is terminated.

Note

If you fail to calibrate the touch panel, you won’t be able to operate the touch panel. If you fail, open the CALIBRATION panel using the mouse connected to the MOUSE connector again, then perform operations of step 5 to 8 again.

6DIM LEVEL section

Adjusts the dimmer level of the monitor signals.

v/V buttons: Increase or decrease the dimmer level of the CR MON (control room monitors) or STUDIO LS (studio monitors). The adjusted values are displayed on the display windows.

KEEP button: Touch this button to store the dimmer level displayed on the window in the current title. At the same time, data in the work area is also stored in the current title.

3 Chapter Menu

Chapter 3 Menu 85