Basic Operation Procedure

4 Chaper Tips Operation

From the previous page

Confirming/setting monitoring

Select the CR MONITOR tab on the MONITOR window (page 59) and confirm that CUT L/CUT R buttons are set to OFF. (Change the settings as required.)

Press the PGM button on the SOURCE section on the control room monitor section on the unit (page 24) so that the button lights up.

Setting the analog head amplifier

Select the INPUT button on the CHANNEL METERS section on the MISC SETUP window (page 84).

Release the INPUT B button on the Analog head amplifier panel (page 11) so that the button is not lit. The IN A connector becomes active.

Watching the meter of the channel (in this example, CH 1) connected to the corresponding head amplifier, adjust the gain using the GAIN control on the Analog head amplifier panel.

In this example, set the PAD button on the Analog head amplifier panel to OFF to connect the microphone. (Set the PAD button to on or off, as required.)

Depress the + 48 V button on the Analog head amplifier, as required.

Note

When devices other than microphones that cannot receive power from the external unit are connected to the IN A connector, release this + 48 V button (not depressed). If you set this button to ON, the connected external unit may be damaged.

Setting the channel

Press the ACCESS button on the channel strip panel (page 12) for CH 1 on the unit so that the button lights up.

Press the PROGRAM L/R buttons on the BUS ASSIGN section (page 18) on the unit. (The signal of the channel is assigned to the PGM bus.)

Set the level of the PROGRAM fader to 0 dB. (Change the level of the PROGRAM fader, as required.)

Watching the master meter (page 22), adjust the level using the channel fader.

Adjust the monitor sound volume using the controls on the Control room monitor section (page 24).

Storing the channel settings as data

To store the channel data, store it as snapshot data using the STORE button on the SNAPSHOT window (page 64).

When restarting the unit or turning off the power of the unit, save data by selecting KEEP on the TITLE menu which opens by touching the TITLE button.

92 Chapter 4 Operation Tips