Menu Windows
EQUALIZER/FILTER Window
To open this window, touch the CHANNEL button on the bottom menu bar, then select “EQUALIZER/ FILTER.” Or, when the CHANNEL window is displayed, touch any point on the EQ/FIL display section.
This window displays the settings on the EQUALIZER section on the Parameter Setting panel of the unit.
If you touch the display window where the numerical value is displayed, that item is set to READY status or automation DROP IN/OUT.
3 Chapter Menu
1Frequency characteristics
graph | 4 EQ IN button |
2LF/LMF/HMF/HF equalizer section
3LF/HF filter section
1Frequency characteristics graph
Displays the total frequency characteristics of the equalizers and filters.
2LF/LMF/HMF/HF equalizer section Displays Q, the level and in/out status of each equalizer section.
FREQ (frequency) display: Displays the frequency set by the FREQ control.
Q display: Displays the setting of the Q control.
LEVEL display: Displays the level set by the LEVEL control on the unit.
IN button: This button puts each equalizer section in and out of the circuit.
/
(equalizer characteristics selector) buttons: These buttons change the equalizer section from a peaking equalizer to a shelving type of equalizer.
3LF/HF filter section
FREQ
Displays the filter’s
IN button: This button puts the filter in and out of circuit.
NOTCH button (only for
4EQ (equalizer) IN button
Touch this button to turn on or off the whole equalizer section. This button is linked to the IN button under the DYNAMICS section on the Parameter Setting panel.
Note
Even if the IN button in each equalizer section is lit, the equalizer/filter sections are not turned on if this button is not lit. Filters are turned on or off regardless of the EQ IN button setting.
46 Chapter 3 Menu