Menu Windows

EQUALIZER/FILTER Window

To open this window, touch the CHANNEL button on the bottom menu bar, then select “EQUALIZER/ FILTER.” Or, when the CHANNEL window is displayed, touch any point on the EQ/FIL display section.

This window displays the settings on the EQUALIZER section on the Parameter Setting panel of the unit.

If you touch the display window where the numerical value is displayed, that item is set to READY status or automation DROP IN/OUT.

3 Chapter Menu

1Frequency characteristics

graph

4 EQ IN button

2LF/LMF/HMF/HF equalizer section

3LF/HF filter section

1Frequency characteristics graph

Displays the total frequency characteristics of the equalizers and filters.

2LF/LMF/HMF/HF equalizer section Displays Q, the level and in/out status of each equalizer section.

FREQ (frequency) display: Displays the frequency set by the FREQ control.

Q display: Displays the setting of the Q control.

LEVEL display: Displays the level set by the LEVEL control on the unit.

IN button: This button puts each equalizer section in and out of the circuit.

/(equalizer characteristics selector) buttons: These buttons change the equalizer section from a peaking equalizer to a shelving type of equalizer.

3LF/HF filter section

FREQ (cut-off frequency) display

Displays the filter’s cut-off frequency set by the FREQ control on the EQUALIZER section on the Parameter Setting panel.

IN button: This button puts the filter in and out of circuit.

NOTCH button (only for low-cut filter): This button turns notch mode ON or OFF. When this button is lit, the low-cut filter acts as a notch filter.

4EQ (equalizer) IN button

Touch this button to turn on or off the whole equalizer section. This button is linked to the IN button under the DYNAMICS section on the Parameter Setting panel.

Note

Even if the IN button in each equalizer section is lit, the equalizer/filter sections are not turned on if this button is not lit. Filters are turned on or off regardless of the EQ IN button setting.