Using the Automatic Isolate Function
The automatic isolate function allows you to remove automation control from selected channel or function. Using this automatic isolate function, you can manually adjust the level, regardless of the stored automation data. Even if the automation item is set to the isolate function, the control will write automation data if dropped in.
This can be used as an automation mode, allowing you to stop previous automation playback, finding a new setting of the control and dropping in.
1 Set the channel or function that has the item you want to adjust to ISOLATE in the AUTOMATION window.
2
3 Start the tape recorder to play, and adjust the sound signal to the proper level.
Repeat level adjustments as required.
4 Rewind the tape and play it back.
5 Drop it at the proper point to set the desired item to WRITE. 6 Stop the tape recorder.
7 Clear ISOLATE of the automation item.
Using the Write Hold Mode
After WRITE HOLD mode is set, controls hold their adjusted position even when the timecode is stopped. This function allows you to hold the fader group.
You can readjust the level without previously stored automation data being replayed when timecode is stopped.
1
2 Set the READY button on the top menu bar to ON, open the OPTION button menu and select the WRITE HOLD mode.
3 Select the FOOT SW button or AUTO button in the PUNCH IN/OUT section in the AUTOMATION window.
Punch in/out is set.
4 Set the automation item to be adjusted to READY. 5 Start the tape recorder.
(Continued)
4 Chaper Tips Operation
Chapter 4 Operation Tips 103