6MEASURE/TEMPO section

When the BARS button is lit on the timecode input section on the Automation panel, the beats and bars are calculated on the settings entered in this section.

AMEASURE selector

BTEMPO display window

COFFSET display window

AMEASURE selector Selects the measures of a tune. First level: n/2, n/4, n/8, n/16 2nd level: n

BTEMPO display window

Touch this part to select and enter the tempo.

COFFSET display window

Touch this part to select and enter the timecode of the first beat of the first measure.

Notes

The values of the measure, beats and MIDI clocks displayed when pressing the BARS button on the Automation panel are estimated values obtained by converting the timecode value based on the information set by MEASURE/TEMPO section. The greater the difference from the timecode set on the OFFSET display window is, the greater the error is.

The automation operation is executed based on the timecode regardless of the setting of the BARS button.

7TIME CODE GENERATOR section

AMODE button

BPRESET button

CSTART button

D SAME AS TIME button

E STOP button

F PRESET/GENERATE

G USER’S BIT display

TIME display window

window

AMODE button

Touch this button to set the operation mode of the built-in timecode generator.

LOCAL

The timecode can be run and stopped using the START/STOP buttons.

SLAVE LOCK

Generates the timecode based on the timecode read by the built-in reader.

SLAVE LOCK (AUTO RUN)

Once the timecode read by the built-in reader runs correctly, the timecode is generated as running automatically generated regardless of the incoming timecode.

EMULATE MTR

Controls using the machine control functions of the unit as the emulation machine. In this mode, a LOCATE command will produce a burst or timecode, allowing the machine using the timecode chase to locate.

3 Chapter Menu

Chapter 3 Menu 79