Chapter 4. Configuring the Library

Fibre Channel Information Screen

This screen provides information on the Fibre Channel connection and controller. To access the Fibre Channel information screen, touch the Fibre Channel button on the first Configuration screen (Figure 4-1).

Loop ID

Loop

number

status:

 

 

UP or

Address

DOWN

 

type:

 

Soft or

 

Hard

 

Figure 4-1The Fibre Channel information screen.

The following describe the buttons on this screen:

Address Changes the library’s current ID number on the Fibre Channel loop. See Soft and Hard Addresses on page 53 for information on how Fibre Channel ID numbers are assigned.

Soft/Hard Fibre Channel devices can either use soft or hard addresses. Soft and Hard Addresses on page 53 describes the differences between the two.

Targ Fibre Channel devices can operate as a Target or as a combined Target/Initiator. Currently, the Spectra 10000 library only supports operation as a Target.

51

Page 51
Image 51
Spectra Logic 10000 manual Fibre Channel Information Screen, 1The Fibre Channel information screen