Chapter 4. Configuring the Library
5.Touch the + and - symbols next to the SCSI Bus 2 ID button to scroll through the SCSI IDs and select the appropriate setting.
6.Touch Save Parms > Yes to restart the library and save changes.
7.Power off the library and reconnect the system SCSI cables.
8.Power on the library, and, after it comes ready, turn on any other peripheral equipment and confirm proper operation of the system.
Note: If the library is in the dual SCSI mode (SCSI busses are not connected with the SCSI link) and SCSI ID 2 is off, Drive 3 and Drive 4 will power up with an error until the second SCSI bus ID is properly configured.
Split-Bus Operation Only: Library 2 Slots
If you configured the library to be shared by two hosts (as two logical libraries), as discussed in Selecting the Mode of Library Operation on page 29, you must configure the Library 2 Slots setting.
Library 2 Slots Defines the slots for the second logical library, allocated in multiples of 10. If you have only configured the library to use one host, leave this setting off.
•Touch the + and - symbols to enable or disable slots, depending on whether you have configured a second logical library.
•Touch Save Parms > Yes to restart the library and have the changes take effect.